Service Monitor LG 710S Sometimes Death Method

Wednesday, May 2nd, 2012 - Business Gallery

Service Monitor LG 710S Sometimes Death Method

The damage was first lit the flame normal monitor, but when turned off by pressing the button and then on power again, LG 710S is not willing to come on again . Service Monitor LG 710S Sometimes Death Method

I first suspected that the damage was in the primary power suplynya, and I think it is difficult, because the damage had been working just as hard not to play. Actually not difficult, but because the damage has not been met so difficult.

OK back to the subject matter:

1. Unloading LG 710S monitor this. Same way as to disassemble samsung monitor.

2. Elco 1000uF/10v check for voltage regulator 15 and 5 volts. Usually this elco swell, causing the output voltage becomes abnormal. Though this voltage required by the ic The major program which a lot of leg work. And the IC is held all the monitor settings, including the on / off it. Service Monitor LG 710S Sometimes Death Method


3. Elco replace it.

4. Completed. Living a try …… Service Monitor LG 710S Sometimes Death Method

 

=====================================

thanks to :

ekohasan blogspot

edited by: twinqu.com

Service Monitor LG 710S Sometimes Death Method | twinqu | 4.5