How To Replace or Modify Flyback Monitor Digital GTC

Wednesday, May 2nd, 2012 - Business Gallery

How To Replace or Modify Flyback Monitor Digital GTC

Replacement Flyback Monitor Flyback GTC Digital 90dengan others who do not use similar / one type. Or most people say “replace flyback”. Want to know how …?

Here’s How to Change the Monitor Flyback GTC Digital: How To Replace or Modify Flyback Monitor Digital GTC

1. Prepare a Flyback replacement, surely you must know the composition of his legs.

This time I used a flyback AOC monitor with foot structure as follows:

1. Colector
2. DIODE dumper
3. NC: NO CONNECTION
4. NC: NO CONNECTION
5. B +
6. NC: NO CONNECTION
7. ABL
8. GROUND
9. AFC
10. G1

B. Note the foot structure which would replace the original flyback

1. colector
2. DIODE dumper
3. B +
4. NC: NO CONNECTION
5. H PHASE
6. AFC (4vac or 40Vdc)
7. ABL
8. G1 (-160vdc)
9. GROUND
10. H PHASE

C. Modified Flyback replacement so that the composition of his legs in accordance with the original flyback. How To Replace or Modify Flyback Monitor Digital GTC

That is so,:

1. Colector: it fits, sama2x foot no. 1

2. DIODE Dumper: it fits, sama2x foot no. 2

3. Should B +, but it was a replacement flyback no.3 feet (AOC) is NC. While his feet B + AOC no.5. Your job is to make the legs go into the socket no.5 AOC Flyback PCB Board no.3. I usually cut off the path and use a cable to connect it.

4. NC: NC is not important, so it would not be connected too is okay.

5. H PHASE: This is also the path that does not matter if you loose. So for H Phase I is not installed.

6. AFC: is equal to B +, replacement flyback AFC foot is on no.9. So make your legs no.9 Flyback PCB connects to the socket 6.

7. ABL: it fits not need to change feet.

8. G1: do not match, so make your legs no. Flyback AOC 10 connects to the socket PCB no. 8 board GTC.

9. GROUND: do not match, so make your legs no. 8 flyback AOC connect to the socket PCB no. 9 board GTC.

10. H Phase: This path is disconnected, because not used it does not matter.


D. Pairs of legs of 10 feet adjacent to the main ground and also the focus and screen wires and cupping flyback.

E. Plug the coil cord is also syncronisasi power supply
If not installed IRF630 sometimes does not work.

F. Adjust the position and location of the foot and cables as neat as possible


G. Ready to try on.

Incidentally this is the practice of media GTC monitor 14 “Digital.
This way not only to monitor the GTC but can also be used for all monitors, but not all monitors easy on bandrek, there are some that are difficult to monitor because of all the legs are used bandrek and no tracks. How To Replace or Modify Flyback Monitor Digital GTC